Quote on 17100 of Robert M Hadley Company Inc with NSN 5950003940659

Part Number: 17100
NIIN: 003940659
Item Name : Transformer Power
CAGE Code: 72964
FSG: 59 Electrical and Electronic Equipment Components
Country: USA
NCB Code: 00

You have arrived on our RFQ form, which we encourage you to complete to the best of your abilities in order to receive tailored quotes on Transformer Power items like part number 17100 by Robert M Hadley Company Inc. Make sure to include information about your operational requirements like your target price, desired part quantity, and expected delivery date. Once you submit this form, an expert account manager will craft a customized quote on part number 17100 with NSN 5950003940659 that has been crafted according to your needs and restrictions alike within 15 minutes of receiving your request.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/customer-terms-and-conditions/ . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

At Vital Purchasing, we prioritize providing our customers with only the highest quality NSN parts and services. As such, we proudly source all of our components such as part number 17100 from leading manufacturers like Robert M Hadley Company Inc, an entity that operates with CAGE Code 72964. More than that, we subject countless items to thorough quality assurance measures to guarantee their caliber prior to purchase, and we boast a global supply-chain network that allows us to expedite shipping times for both domestic and international orders to accommodate those with rigid time constraints. Begin the procurement process for all the FSC 5950 Coils and Transformers related parts you require today to see how we can simplify part sourcing for you.

NSN Information for Part Number 17100 with NSN 5950-00-394-0659, 5950003940659

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5950-00-394-0659

Item PartTypeName:

TRANSFORMER,POWER

59500039406590P
CIICHCCESDPMICCriticalityENAC
UA
Part NumberISCRNVCRNCCHCCMSDSSADC
17100625

Characteristics Data of NSN 5950-00-394-0659, 5950003940659

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.609 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.641 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZXWINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
ADAQBODY LENGTH3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM
ADATBODY WIDTH2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM
ADAUBODY HEIGHT4.687 INCHES MINIMUM AND 4.875 INCHES MAXIMUM
AEHZMAXIMUM OPERATING TEMP105.0 DEG CELSIUS
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
CRBZWINDING OPERATING CURRENT5.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT5.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT5.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT5.0 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY20.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY4.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY4.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
FEATSPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS,SIXTH SECONDARY HAS MULTIPLE TAPS W/O CENTER TAP
THSDTHREAD SERIES DESIGNATORUNC SINGLE GROUP
TTQYTERMINAL TYPE AND QUANTITY23 SOLDER STUD

Related NSN Components of 17100

A Complete NSN Part Purchasing Platform

  • AS9120B and ISO 9001:2015
  • Aviation Suppliers Association Member
  • FAA AC 0056B Accredited
  • AS 6081:2012 Certification
  • ESD S20.20-2014 Certification

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.