You have arrived on our RFQ form, which we encourage you to complete to the best of your abilities in order to receive tailored quotes on Relay Electromagnetic items like part number 1004X by Tyco Electronics Corporation. Make sure to include information about your operational requirements like your target price, desired part quantity, and expected delivery date. Once you submit this form, an expert account manager will craft a customized quote on part number 1004X with NSN 5945012933976 that has been crafted according to your needs and restrictions alike within 15 minutes of receiving your request.
Note : We Will Not Share Your Information To Any Third Parties.
At Vital Purchasing, we prioritize providing our customers with only the highest quality NSN parts and services. As such, we proudly source all of our components such as part number 1004X from leading manufacturers like Tyco Electronics Corporation, an entity that operates with CAGE Code 18741. More than that, we subject countless items to thorough quality assurance measures to guarantee their caliber prior to purchase, and we boast a global supply-chain network that allows us to expedite shipping times for both domestic and international orders to accommodate those with rigid time constraints. Begin the procurement process for all the FSC 5945 Relays and Solenoids related parts you require today to see how we can simplify part sourcing for you.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-293-3976 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 012933976 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1004X | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.850 INCHES MINIMUM AND 3.910 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.470 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.720 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.780 INCHES MINIMUM AND 3.830 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.470 INCHES MINIMUM AND 3.530 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.161 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.181 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY DELICATE |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 51.739 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CRXH | TIME DELAY | 5.00 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 460.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 230.0 AC AND 28.0 DC |
FEAT | SPECIAL FEATURES | 3 PHASE COIL |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TAB W/SCREW ALL FUNCTIONS |